Manganese Greensand Filter
Sizing
Operation Conditions:
- Ph must be within 6.6 and 8.8
- Well Pump water flow must be greater than the
backwash rate in system specifications.
Removal per cubic feet
- 15 ppm of both ferric (oxidized) and
ferrous (clear) iron
- 05 ppm of Hydrogen sulfide (rotten egg
odor)
- 10 ppm of manganese
System Capacity per cubic feet based on type of
contaminant present in the application
- Iron Alone: 10,000 gallons of water containing 1 ppm
iron/cu. ft
- Iron and Manganese: 7,000 gallons of water containing
1/2 ppm iron and 1/2 ppm of manganese/ cu ft.
- Hydrogen Sulfide: 3,000 gallons of water containing 1 ppm
hydrogen sulfide/cu. ft.
Given that system operation conditions are met, please use the
chart below to size your system.
| Legend |
Color |
|
| Model 56GRE-10 |
|
|
| Model 56GRE-15 |
|
|
| Model PRGRE-10 |
|
|
| Call for Sizing |
|
|
Iron Alone:
- Iron present in the application
- Manganese has being tested and not detected
- Hydrogen Sulfide has being tested and not detected. No
rotten egg odor is present in the application.
Iron
ppm= mg/l |
Number of People in Household / Estimated
Daily Water Consumption |
|
1/80 |
2/160 |
3/240 |
4/320 |
5/400 |
6/480 |
7/560 |
8/640 |
| 1 |
|
|
|
|
|
|
|
|
| 2 |
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
| 7 |
|
|
|
|
|
|
|
|
| 8 |
|
|
|
|
|
|
|
|
| 9 |
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
| 11 |
|
|
|
|
|
|
|
|
| 12 |
|
|
|
|
|
|
|
|
| 13 |
|
|
|
|
|
|
|
|
| 14 |
|
|
|
|
|
|
|
|
| 15 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Iron and Manganese
- Iron and Manganese has being detected on the application.
- Either Iron or Manganese level is unknown.
- Hydrogen Sulfide has being tested and not detected. No
rotten egg odor is present in the application.
Iron + Manganese
ppm= mg/l |
Number of People in Household / Estimated
Daily Water Consumption |
|
1/120 |
2/240 |
3/360 |
4/480 |
5/600 |
6/720 |
7/840 |
8/960 |
| 1 |
|
|
|
|
|
|
|
|
| 2 |
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
| 7 |
|
|
|
|
|
|
|
|
| 8 |
|
|
|
|
|
|
|
|
| 9 |
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
| 11 |
|
|
|
|
|
|
|
|
| 12 |
|
|
|
|
|
|
|
|
| 13 |
|
|
|
|
|
|
|
|
| 14 |
|
|
|
|
|
|
|
|
| 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hydrogen Sulfide
- Hydrogen Sulfide has being tested and detected or rotten
egg odor is present in the application.
| Hydrogen Sulfide ppm= mg/l |
Number of People in Household / Estimated
Daily Water Consumption |
|
1/120 |
2/240 |
3/360 |
4/480 |
5/600 |
6/720 |
7/840 |
8/960 |
| 1 |
|
|
|
|
|
|
|
|
| 2 |
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|